Technical Details
-
Part Status
Active
-
Type
Enclosed
-
Number of Outputs
1
-
Voltage - Input
80 ~ 264 VAC
-
Voltage - Output 1
24V
-
Voltage - Output 2
-
-
Voltage - Output 3
-
-
Voltage - Output 4
-
-
Voltage - Output 5
-
-
Voltage - Output 6
-
-
Current - Output 1
50 A
-
Power (Watts)
1200W
-
Applications
ITE (Commercial), Laboratory
-
Voltage - Isolation
4 kV
-
Efficiency
95%
-
Operating Temperature
-40°C ~ 80°C (With Derating)
-
Features
Adjustable Output, Baseplate, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output
-
Mounting Type
Chassis Mount
-
Size / Dimension
8.98" L x 3.79" W x 1.57" H (228.0mm x 96.2mm x 40.0mm)
-
Approval Agency
CE, cURus, EAC
-
Standard Number
61010-1; 62368-1
-
Minimum Load Required
No
-
RoHS Status
ROHS3 Compliant
-
Moisture Sensitivity Level (MSL)
1 (Unlimited)
-
REACH Status
REACH Unaffected
-
ECCN
EAR99
-
HTSUS
8504.40.9540